Fully adjustable, pressure-compensated flow controls with reverse-flow check provide precise flow regulation for meter-in or meter-out applications where there may be wide pressure fluctuations. They are infinitely adjustable from nearly closed up to the maximum flow. An integral high-capacity check valve provides unrestricted flow from port 2 to port 1.

  • All 2-port flow control cartridges are physically and functionally interchangeable (i.e. same flow path, same cavity for a given frame size). However, cartridge extension dimensions from the mounting surface may vary.
  • A balanced adjustment mechanism allows for easy adjustment even at high pressures.
  • The sharp-edged orifice design minimizes flow variations due to viscosity changes.
  • Minimum leakage is .1 gpm (0,4 L/min) when the adjustment mechanism is turned to the shut-off position.
  • Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.

Back to Top

Note: Data may vary by configuration. See CONFIGURATION section.

Cavity T-13A
Series 1
Capacity 6 gpm23 L/min.
Maximum Operating Pressure 5000 psi350 bar
Adjustment - No. of CCW Turns from Fully Closed to Fully Open 55
Valve Hex Size 7/8 in.22,2 mm
Valve Installation Torque 30 - 35 lbf ft41 - 47 Nm
Adjustment Screw Internal Hex Size 5/32 in.4 mm
Locknut Hex Size 9/16 in.15 mm
Locknut Torque 80 - 90 lbf in.9 - 10 Nm
Model Weight .40 lb0,20 kg
Seal kit - Cartridge Buna: 990010007
Seal kit - Cartridge EPDM: 990010014
Seal kit - Cartridge Polyurethane: 990010002
Seal kit - Cartridge Viton: 990010006

Back to Top

What is the pressure drop through a flow control?

In a meter-in flow control circuit if the pump is set at 3000 psi and the load is 2000 psi the drop through the flow control is 1000 psi. In a meter-out circuit with the load at 2000 psi the drop through the flow control is 2000 psi.

How accurate are Sun's flow controls?

We claim +/- 10%. We set to +/- 5% in production testing to allow for differences in customers' conditions. If you want accuracy, stay in the bottom 2/3rds of the range. Our 12 gpm (45 L/min.) flow controls are quite flat at 9 gpm (34 L/min.) and dead flat below 6 gpm (23 L/min.), until you get to the bottom of the range. Below about .25 gpm (1 L/min.), spool leakage and orifice conditions start to limit accuracy.

I have a heat problem, will Sun's priority flow control help?

I am afraid not. Unless you are overflowing your current valve and correctly size ours, you are not likely to notice any improvement. Priority flow controls are not efficient devices. They are an easy way to get more than 1 source of oil from 1 pump but they can generate a lot of heat. Try to size your actuators so the pressures are similar on both the priority and the bypass circuits. If you can't do that, try to have the lower flow leg be the lower pressure. The pump pressure is determined by whichever leg is higher and if there is flow that is taking a pressure drop that is not doing work it is creating heat.

What happens if I block the control flow (priority) port?

All flow is blocked, hence the term priority. The priority flow has to be satisfied.

What happens if I block the bypass port on a priority flow control?

The valve acts as a 2 port restrictive flow control.

What is the compensating pressure of Sun's flow controls?

The spring force in our flow controls equates to about 100 psi (7 bar). This is high enough to give the valves acceptable capacity and not too high for proper circuit operation. 100 psi (7 bar) is the spring force; at the upper end of the flow control's range, the drop through the valve will be as high as 250 psi (17 bar) before it starts modulating.

How big is a drop of hydraulic oil?

There are exactly 250 Sun drops in a cubic inch or 15 in a cc.

What parts of the Sun cartridge valve are field serviceable?

Only external seals are serviceable. Sun offers replacement seal kits for all cartridge models. Theapplicable kit part number can be found in the product page's Technical Data table or by using our Cartridge Seal Kitsearch function located under Accessories. Please note: Converting the external seals from one material to another does not ensure fluid compatibility with that material due to the existence of internal seals within the cartridge.

Back to Top

FDBALBN/LH | Cartridges » Flow Control » Flow Control (2024)
Top Articles
Latest Posts
Article information

Author: Rueben Jacobs

Last Updated:

Views: 6258

Rating: 4.7 / 5 (77 voted)

Reviews: 92% of readers found this page helpful

Author information

Name: Rueben Jacobs

Birthday: 1999-03-14

Address: 951 Caterina Walk, Schambergerside, CA 67667-0896

Phone: +6881806848632

Job: Internal Education Planner

Hobby: Candle making, Cabaret, Poi, Gambling, Rock climbing, Wood carving, Computer programming

Introduction: My name is Rueben Jacobs, I am a cooperative, beautiful, kind, comfortable, glamorous, open, magnificent person who loves writing and wants to share my knowledge and understanding with you.